□RN2型户内高压限流熔断器,用于电压互感器的保护,其断流容量为1000MVA。在短路时以限制线路电流到最小值的方式进行瞬 时开断,1分钟内熔断电流应在0.6-1.8A范围内。
□The product is used in overload or short-circuit protection for instrument transformer.At the time of holding up by restrain circuit current way to get minimum from carry on instantaneous to turn on and break,it should be within the range of 0.6-1.8A to fuse the electric current in one minute.
◆技术数据Technique data
产品型号 Product type | RN2-3、6、10 | RN215、20 | RN2-35 | |||
额定电压Rated voltage KV | 3 | 6 | 10 | 15 | 20 | 35 |
额定电流Fuse current A | 0.5 | 0.5 | ||||
三相断流容量Capacity of largest break of three-phase MVA | 500 | 100 | 1000 | 1000 | ||
**开断电流(有效值) Max break curent KA effective value KA | 100 | 85 | 50 | 40 | 30 | 17 |
过电压倍数Overvoltage multiple Do not exceed | 不超过2.5倍工作电压Do not exceed voltage of 2.5 times of rating | |||||
熔管电阻值Resistance of the fuse pipe(Ω) | 93±7 | 200±10 | 315±14 | |||
重量Weight Kg | 5.6 | 12.2 | 15.6 | |||
熔管重量Fuse weight Kg | 0.9 | 1.6 | 2.5 |